Current Imbalance Analysis in Three-Phase Induction Motors: Causes, Performance Impacts, and Mitigation Efforts

Authors

  • Muh. Rizky Antro Universitas Muhammadiyah Gresik
  • Muh. Iqbal Maulana Universitas Muhammadiyah Gresik
  • Naufal Fahmi Alfasa Universitas Muhammadiyah Gresik
  • Hendri Suryo Frans De Nero Universitas Muhammadiyah Gresik
  • Wahyu Angga Putra Wardana Universitas Muhammadiyah Gresik

DOI:

https://doi.org/10.61536/ambidextrous.v5i01.993

Keywords:

Current Imbalance, Three-Phase Induction Motor, Voltage Unbalance, Derating, Single-Phasing

Abstract

The three-phase induction motor is the most widely used electromechanical drive in the industrial sector due to its simple construction, reliability, and relatively low cost. However, its performance strongly depends on the quality of a balanced three-phase voltage supply. Even a small voltage unbalance is amplified into a much larger stator current unbalance, causing excessive heating, reduced efficiency, torque and speed oscillation, increased vibration, and accelerated degradation of winding insulation. This article aims to analyze, through a literature-based approach, the causes, mechanisms, calculation methods, impacts, and mitigation strategies of current imbalance in three-phase induction motors by synthesizing previous studies, both simulation-based (MATLAB/Simulink) and experimental laboratory/industrial testing. The method used is a literature review of national scientific articles in electrical engineering discussing voltage/current unbalance in induction motors. The review shows that, based on the NEMA standard, a 1% voltage unbalance can produce approximately 6-10 times greater current unbalance, and at 5% voltage unbalance the motor experiences significant overheating requiring derating of about 25% of its rated capacity. Extreme conditions such as single-phasing faults can cause voltage unbalance of 3.64%-6.30% accompanied by a sharp temperature rise that risks damaging winding insulation. Recommended mitigation strategies include real-time current and voltage monitoring based on the Internet of Things (IoT), phase-unbalance and single-phasing protection, motor derating according to the NEMA standard, and preventive maintenance of the three-phase supply system. This review is expected to serve as a reference for further research on the protection and reliability of three-phase induction motors in industrial settings.

Downloads

Download data is not yet available.

References

M. D. T. Sogen, “Analisis pengaruh ketidakseimbangan beban terhadap arus netral dan losses pada transformator distribusi di PT PLN (Persero) Area Sorong,” J. Electro Luceat, vol. 4, no. 1, pp. 1–8, 2018.

E. Julianto, “Studi pengaruh ketidakseimbangan pembebanan transformator distribusi 20 kV PT PLN (Persero) Cabang Pontianak,” Jurnal Teknik Elektro Universitas Tanjungpura, vol. 2, no. 1, pp. 1–6, 2016.

A. Kadir, Transformator. Jakarta: PT Elex Media Komputindo, 1989.

T. S. Hutauruk, Transmisi Daya Listrik. Jakarta: Penerbit Erlangga, 1985.

IEEE Std 446-1995, “IEEE Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications,” Institute of Electrical and Electronics Engineers, 1995.

R. T. Ginting, Zulfahri, and Arlenny, “Analisis ketidakseimbangan beban jaringan distribusi tegangan rendah menggunakan ETAP,” SainETIn (J. Sain, Energi, Teknol. & Industri), vol. 6, no. 2, pp. 81–89, 2022, doi: 10.31849/sainetin.v6i2.9734.

A. R. Sutejo, Sutedjo, M. M. Rifadil, and R. Salsabila, “Penyeimbangan beban sistem kelistrikan tiga fasa berbasis fuzzy logic,” TELKA, vol. 9, no. 1, pp. 1–8, 2023.

A. B. Prayoga and B. Suprianto, “Analisis pengaruh ketidakseimbangan beban pada transformator distribusi terhadap rugi daya (losses) dengan DIgSILENT Power Factory di PT PLN (Persero) ULP Ngunut,” J. Tek. Elektro, vol. 12, no. 2, pp. 23–32, May 2023, doi: 10.26740/jte.v12n2.p23-32.

R. Hidayat, M. Masarrang, Y. Arifin, B. Mukhlis, A. A. Adam, and Y. S. Pirade, “Studi analisis ketidakseimbangan beban pada transformator distribusi dan efeknya terhadap kinerja transformator serta aliran daya di PT PLN (Persero) UP3 Palu menggunakan DIgSILENT Power Factory,” Foristek, vol. 16, no. 1, pp. 1–16, 2026, doi: 10.54757/fs.v16i1.933.

I. W. Sutama and I. A. L. N. Sari, “Analisis ketidakseimbangan beban pada gardu distribusi KA 0251 Penyulang Gelogor Carik,” J. Ilm. Telsinas Elektro, Sipil dan Tek. Inform., vol. 6, no. 2, pp. 209–218, 2023, doi: 10.38043/telsinas.v6i2.4893.

Zulkhulaifah, Bakhtiar, and H. Rudito, “Analisis pengaruh ketidakseimbangan beban trafo distribusi 20 kV terhadap rugi-rugi daya dan efisiensi pada Penyulang Hertasning Baru PT PLN (Persero) ULP Panakukkang Makassar,” in Pros. Semin. Nas. Tek. Elektro dan Inform. (SNTEI), Makassar, Indonesia, Sep. 21, 2021, pp. 6–11.

H. B. Jatmiko, A. Trihasto, and D. Pravitasari, “Evaluasi ketidakseimbangan beban terhadap arus netral pada transformator di Gardu Induk 150 kV Secang,” RELE (Rekayasa Elektrikal dan Energi): Jurnal Teknik Elektro, vol. 7, no. 1, pp. 226–233, 2024, doi: 10.30596/rele.v7i1.20350.

R. Ammarsaputra and F. H. Rumawan, “Analisis pengaruh ketidakseimbangan beban terhadap arus netral dan rugi-rugi daya pada transformator daya di Gardu Induk Bukuan,” ELECTROPS: J. Ilm. Tek. Elektro, vol. 3, no. 1, pp. 27–38, 2024, doi: 10.30872/electrops.v3i1.19583.

Z. Maulia, W. Aribowo, S. I. Haryudo, and Joko, “Analisis kualitas daya berdasarkan keseimbangan beban tiga fasa pada instalasi listrik Gedung I8 Fakultas Ilmu Sosial dan Hukum Universitas Negeri Surabaya,” J. Tek. Elektro, vol. 10, no. 3, pp. 619–628, 2021, doi: 10.26740/jte.v10n3.p619-628.

D. N. Jamia and T. Taryo, “Load balancing optimization analysis of 630 kVA transformer to reduce neutral current at KSBI Cirebon substation,” Jambura J. Electr. Electron. Eng., vol. 8, no. 2, pp. 150–159, 2026, doi: 10.37905/jjeee.v8i2.38205.

W. O. S. Hajriani F. A., Marwan, and S. Thaha, “Studi pengaruh ketidakseimbangan beban trafo distribusi 20 kilovolt terhadap rugi-rugi daya pada Penyulang Toddopuli PT Perusahaan Listrik Negara (Persero) Unit Layanan Pelanggan Panakukkang

Downloads

Published

2026-11-12

How to Cite

Muh. Rizky Antro, Muh. Iqbal Maulana, Naufal Fahmi Alfasa, Hendri Suryo Frans De Nero, & Wahyu Angga Putra Wardana. (2026). Current Imbalance Analysis in Three-Phase Induction Motors: Causes, Performance Impacts, and Mitigation Efforts. Ambidextrous Journal of Innovation Efficiency and Technology in Organization, 5(01), 171–177. https://doi.org/10.61536/ambidextrous.v5i01.993

Similar Articles

1 2 > >> 

You may also start an advanced similarity search for this article.